Thermal Fuses 172°C 10(8)A
Varenummer:
151-647
Varekode: TZ-D-172
Vægt: 3 g
9 stk.
på lager
Specifikationer
| Temperatur | 172 °C |
|---|---|
| Strøm, max. | 10 A |
| Features |
| For installation on or in the heating device of electric
household appliances, transformers and all types of devices Switches off devices if the premissible operating temperature is exceeded After activating, the fuse must be replaced Secured in dust and dirt proof enclosure Reacts to surrounding temperatures and is conditionally current sensitive during rated loads |
| Technical
Specifications |
| Contact: | NC |
| Rated Current | |
| VDE, CSA: | 10A |
| UL: | 8A |
| Rated Voltage: | 250V AC |
| Part Nr. | TRated | TH | TMax |
| [°C] | [°C] | [°C] | |
| E4A072 | 72 | 47 | 100 |
| E4A093 | 93 | 68 | 140 |
| E4A098 | 98 | 73 | 140 |
| E4A104 | 104 | 79 | 150 |
| E4A117 | 117 | 92 | 160 |
| E4A121 | 121 | 96 | 160 |
| E4A128 | 128 | 103 | 210 |
| E4A167 | 167 | 142 | 210 |
| E4A192 | 192 | 167 | 210 |
| E4A216 | 216 | 191 | 375 |
| E4A240 | 240 | 200 | 450 |
| TRated= Rated Temperature, TH= Continuous Operating Temperature, TMax= Max. Limiting Temperature | |||
| Note |
| The self-heating current is to be taken into consideration
when using the thermal fuse Thermal fuses with separate ventilation can lead to higher currents |
| Approvals |
![]() ![]() ![]() |
Inkl. moms
Kr. 13,95
- v/10 – Kr. 6,88
- v/100 – Kr. 4,69
Produktfiler
Thermal Fuses 172°C 10(8)A
151-647
/ TZ-D-172
9 stk.
på lager
Specifikationer
- Temperatur 172 °C
- Strøm, max. 10 A
| Features |
| For installation on or in the heating device of electric
household appliances, transformers and all types of devices Switches off devices if the premissible operating temperature is exceeded After activating, the fuse must be replaced Secured in dust and dirt proof enclosure Reacts to surrounding temperatures and is conditionally current sensitive during rated loads |
| Technical
Specifications |
| Contact: | NC |
| Rated Current | |
| VDE, CSA: | 10A |
| UL: | 8A |
| Rated Voltage: | 250V AC |
| Part Nr. | TRated | TH | TMax |
| [°C] | [°C] | [°C] | |
| E4A072 | 72 | 47 | 100 |
| E4A093 | 93 | 68 | 140 |
| E4A098 | 98 | 73 | 140 |
| E4A104 | 104 | 79 | 150 |
| E4A117 | 117 | 92 | 160 |
| E4A121 | 121 | 96 | 160 |
| E4A128 | 128 | 103 | 210 |
| E4A167 | 167 | 142 | 210 |
| E4A192 | 192 | 167 | 210 |
| E4A216 | 216 | 191 | 375 |
| E4A240 | 240 | 200 | 450 |
| TRated= Rated Temperature, TH= Continuous Operating Temperature, TMax= Max. Limiting Temperature | |||
| Note |
| The self-heating current is to be taken into consideration
when using the thermal fuse Thermal fuses with separate ventilation can lead to higher currents |
| Approvals |
![]() ![]() ![]() |
Produktfiler