Relay DPDT 2A 12V 960R G5V-2-H1 12VDC
Varenummer:
88-726
Varekode: G5V-2-H1
Vægt: 6 g
27 stk.
på lager
Specifikationer
| Relæ kontakt | DPDT |
|---|---|
| Spolemodstand | 960 Ω |
| Mærkestrøm | 2 A |
| Spolespænding | 12 V |
G5V-2 Low Signal Relay
General-purpose, Low-cost, Two-pole Relays for Signal Circults
- General-purpose DIL terminal layout.
- Wide switching power of 10 µA to 2 A.
- Fully-sealed type Relays standardized with bifurcated crossbar contacts. Highly reliable in addition to its high environment resistance.
- Conforms to FCC Part 68 (impulse withstand voltage of 1,500 V for 10 x 160 νs between coil and contacts and between contacts of the same polarity).
- High dielectric strength at 1,000 VAC between coil and contacts, and 750 VAC between contacts of the same polarity.
- UL and CSA standard approved.
| Classification | Enclosure rating | Contact form | Terminal shape | Model | Rated coil voltage | Minimum packing unit |
|---|---|---|---|---|---|---|
| Standard | Fully sealed |
DPDT(2c) | PCB terminals |
G5V-2 | 3 VDC | 25 pcs/tube |
| 5 VDC | ||||||
| 6 VDC | ||||||
| 9 VDC | ||||||
| 12 VDC | ||||||
| 24 VDC | ||||||
| 48 VDC | ||||||
| High-sensitivity | G5V-2-H1 | 5 VDC | ||||
| 12 VDC | ||||||
| 24 VDC | ||||||
| 48 VDC |
| Note: | When ordering, add the rated coil voltage to the model number. |
| However, the notation of the coil voltage on the product case as well as on the packing will be marked as â–¡â–¡ VDC. |
| Coil Ratings Standard Models
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
High Sensitivity Models
|
|||||||||||||||||||||||||||||||||||||||||||||
Contact Ratings
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Characteristics
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTE: | The above values are initial values. | |
| 1. | The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. | |
| 2. | The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength. | |
| 3. | This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. |
Inkl. moms
Kr. 29,83
- v/10 – Kr. 25,39
- v/25 – Kr. 21,79
- v/100 – Kr. 15,68
- v/1000 – Kr. 12,07
Produktfiler
Relay DPDT 2A 12V 960R G5V-2-H1 12VDC
88-726
/ G5V-2-H1
27 stk.
på lager
Specifikationer
- Relæ kontakt DPDT
- Spolemodstand 960 Ω
- Mærkestrøm 2 A
- Spolespænding 12 V
G5V-2 Low Signal Relay
General-purpose, Low-cost, Two-pole Relays for Signal Circults
- General-purpose DIL terminal layout.
- Wide switching power of 10 µA to 2 A.
- Fully-sealed type Relays standardized with bifurcated crossbar contacts. Highly reliable in addition to its high environment resistance.
- Conforms to FCC Part 68 (impulse withstand voltage of 1,500 V for 10 x 160 νs between coil and contacts and between contacts of the same polarity).
- High dielectric strength at 1,000 VAC between coil and contacts, and 750 VAC between contacts of the same polarity.
- UL and CSA standard approved.
| Classification | Enclosure rating | Contact form | Terminal shape | Model | Rated coil voltage | Minimum packing unit |
|---|---|---|---|---|---|---|
| Standard | Fully sealed |
DPDT(2c) | PCB terminals |
G5V-2 | 3 VDC | 25 pcs/tube |
| 5 VDC | ||||||
| 6 VDC | ||||||
| 9 VDC | ||||||
| 12 VDC | ||||||
| 24 VDC | ||||||
| 48 VDC | ||||||
| High-sensitivity | G5V-2-H1 | 5 VDC | ||||
| 12 VDC | ||||||
| 24 VDC | ||||||
| 48 VDC |
| Note: | When ordering, add the rated coil voltage to the model number. |
| However, the notation of the coil voltage on the product case as well as on the packing will be marked as â–¡â–¡ VDC. |
| Coil Ratings Standard Models
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
High Sensitivity Models
|
|||||||||||||||||||||||||||||||||||||||||||||
Contact Ratings
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Characteristics
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| NOTE: | The above values are initial values. | |
| 1. | The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. | |
| 2. | The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength. | |
| 3. | This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. |