| Application area |
Suitable for indoor installation and outdoor installation, protected against weather influences according to DIN VDE 0100 Part 737 |
| Resistant to occasional cleaning procedures (direct jet) |
Resistant to occasional cleaning procedures (direct jet) with high-pressure cleaner without additives, water pressure: max. 100 bar, water temperature: max. 80� C, distance => 0,15 m, in accordance with the requirements IP 69K, enclosure and cable glands at least IP 65 |
| ambient temperature |
Maximum value + 40� C Minimum value - 25� C |
| Fire protection in the event of internal faults |
Demands placed on electrical devices from standards and laws Minimum requirements - Glow wire test in accordance with IEC 60 695-2-11: - 650�C for boxes and cable glands - 850�C for parts of insulating material necessary to retain current carrying parts in position |
| Fire protection in the event of specific risks or hazards |
Demands placed on electrical devices from standards and laws Minimum requirements - Glow wire test in accordance with IEC 60 695-2-11: - 650�C for boxes and cable glands - 850�C for parts of insulating material necessary to retain current carrying parts in position |
| Burning behavior |
Glow wire test IEC 60 695-2-11: 750� C UL Subject 94 V-2 flame resistant self-extinguishing |
| degree of protection against mechanical load |
IK07 (2 Joule) |
| Toxic behavior |
halogen-free silicone-free "halogen-free" in accordance with the examination of the cables and insulated wires - corrosiveness of fumes - as per IEC 754-2 |
| Note: |
To material properties see technical data. |