DC/AC-Inverter 12V/230V 1000W
Varenummer:
106-101
Varekode: A301-1K0-F3
Vægt: 4375 g
1 stk.
på lager
Gruppe: L9125
MEANWELL DC/AC Converters
Series: A30_-1K0-F3
With Modified Sine Wave Output
Output: 1000W
MEANWELL DC/AC Converters
Series: A30_-1K0-F3
With Modified Sine Wave Output
Output: 1000W
| Features |
| Modified sine wave output Power On/Off switch Front panel indicator for operation status Battery low alarm, Battery low shutdown Protections: over voltage/over temperature/overload/output short/input reverse polarity Built-in fan On/Off control function |
| Technical Specifications |
| Input Voltage: | See Table |
| Output Voltage: | 230V AC |
| Output Frequency: | 50Hz ±1% |
| Output Rated Power: | 1000W |
| Output Sorge Power: | 2400W |
| Wave Form: | Modified Sine Wave |
| Overvoltage | |
| A301-1K0-F3: | 15...16V |
| A302-1K0-F3: | 29...31V |
| Operating Temperature | |
| 100% Load: | 0...+30C |
| 70% Load: | 0...+40C |
| Weight: | 3300g |
| Part Nr. | UE | IE | UBA | UBL | h |
| [V] | [A] | [V] | [V] | [%] | |
| A301-1K0-F3 | 10...15 | 110 | 10±0,5 | 9,5±0,5 | 82 |
| A302-1K0-F3 | 21...30 | 55 | 21±0,8 | 20±0,8, | 85 |
| UE = Input Voltage Range, IA = Input Current, UBA = Battery Low Alarm, UBL = Battery Shutdown, h = Efficiency | |||||
| Note |
| Before using the DC/AC converter, please ensure that your terminal equipment has been approved by the manufacturer for operation with modified sine-wave voltage (trapezoid). |
| Labelling |
|
| Terms of Delivery |
| Minimum order quantity: 1 PKU = 1 piece Articles in bold print in stock, other articles of 1 piece upwards available on request, delivery time approx. 14 weeks. |
| Manufacturer |
|
| http://www.meanwell.com |
Inkl. moms
Kr. 2499,00
Produktfiler
DC/AC-Inverter 12V/230V 1000W
106-101
/ A301-1K0-F3
1 stk.
på lager
Gruppe: L9125
MEANWELL DC/AC Converters
Series: A30_-1K0-F3
With Modified Sine Wave Output
Output: 1000W
MEANWELL DC/AC Converters
Series: A30_-1K0-F3
With Modified Sine Wave Output
Output: 1000W
| Features |
| Modified sine wave output Power On/Off switch Front panel indicator for operation status Battery low alarm, Battery low shutdown Protections: over voltage/over temperature/overload/output short/input reverse polarity Built-in fan On/Off control function |
| Technical Specifications |
| Input Voltage: | See Table |
| Output Voltage: | 230V AC |
| Output Frequency: | 50Hz ±1% |
| Output Rated Power: | 1000W |
| Output Sorge Power: | 2400W |
| Wave Form: | Modified Sine Wave |
| Overvoltage | |
| A301-1K0-F3: | 15...16V |
| A302-1K0-F3: | 29...31V |
| Operating Temperature | |
| 100% Load: | 0...+30C |
| 70% Load: | 0...+40C |
| Weight: | 3300g |
| Part Nr. | UE | IE | UBA | UBL | h |
| [V] | [A] | [V] | [V] | [%] | |
| A301-1K0-F3 | 10...15 | 110 | 10±0,5 | 9,5±0,5 | 82 |
| A302-1K0-F3 | 21...30 | 55 | 21±0,8 | 20±0,8, | 85 |
| UE = Input Voltage Range, IA = Input Current, UBA = Battery Low Alarm, UBL = Battery Shutdown, h = Efficiency | |||||
| Note |
| Before using the DC/AC converter, please ensure that your terminal equipment has been approved by the manufacturer for operation with modified sine-wave voltage (trapezoid). |
| Labelling |
|
| Terms of Delivery |
| Minimum order quantity: 1 PKU = 1 piece Articles in bold print in stock, other articles of 1 piece upwards available on request, delivery time approx. 14 weeks. |
| Manufacturer |
|
| http://www.meanwell.com |