DC/AC-Inverter 12V/230V 300W
Varenummer:
106-097
Varekode: A301-300-F3
Vægt: 1187 g
2 stk.
på lager
Gruppe: L9122
MEANWELL DC/AC Converters
Series: A30_-300-F3
With Modified Sine Wave Output
Output: 300W
MEANWELL DC/AC Converters
Series: A30_-300-F3
With Modified Sine Wave Output
Output: 300W
| Features |
| Modified sine wave output Power On/Off switch Front panel indicator for operation status Battery low alarm, Battery low shutdown Protections: over voltage/over temperature/overload/output short/input reverse polarity Built-in fan On/Off control function |
| Technical Specifications |
| Input Voltage: | See Table |
| Output Voltage: | 230V AC |
| Output Voltage Tolerance: | ±10% |
| Output Frequency: | 50Hz ±1% |
| Output Rated Power: | 300W |
| Peak Power: | 600W |
| Wave Form: | Modified Sine Wave |
| Overvoltage | |
| A301-300-F3: | 15...17V |
| A302-300-F3: | 30...32V |
| Operating Temperature | |
| 100% Load: | 0...+30C |
| 50% Load: | 0...+40C |
| Weight: | 1100g |
| Part Nr. | UE | IE | UBA | UBL | h |
| [V] | [A] | [V] | [V] | [%] | |
| A301-300-F3 | 12 | 0...35 | 10±0,5 | 9,5±0,5 | 82 |
| A302-300-F3 | 24 | 0...15 | 20±0,8 | 19,5±0,8 | 85 |
| UE = Input Voltage Range, IE = Input Current, UBA = Battery Low Alarm, UBL = Battery Shutdown, h = Efficiency | |||||
| Note |
| Before using the DC/AC converter, please ensure that your terminal equipment has been approved by the manufacturer for operation with modified sine-wave voltage (trapezoid). |
| Labelling |
|
| Terms of Delivery |
| Minimum order quantity: 1 PKU = 1 piece |
| Manufacturer |
|
| http://www.meanwell.com |
Inkl. moms
Kr. 799,00
Produktfiler
DC/AC-Inverter 12V/230V 300W
106-097
/ A301-300-F3
2 stk.
på lager
Gruppe: L9122
MEANWELL DC/AC Converters
Series: A30_-300-F3
With Modified Sine Wave Output
Output: 300W
MEANWELL DC/AC Converters
Series: A30_-300-F3
With Modified Sine Wave Output
Output: 300W
| Features |
| Modified sine wave output Power On/Off switch Front panel indicator for operation status Battery low alarm, Battery low shutdown Protections: over voltage/over temperature/overload/output short/input reverse polarity Built-in fan On/Off control function |
| Technical Specifications |
| Input Voltage: | See Table |
| Output Voltage: | 230V AC |
| Output Voltage Tolerance: | ±10% |
| Output Frequency: | 50Hz ±1% |
| Output Rated Power: | 300W |
| Peak Power: | 600W |
| Wave Form: | Modified Sine Wave |
| Overvoltage | |
| A301-300-F3: | 15...17V |
| A302-300-F3: | 30...32V |
| Operating Temperature | |
| 100% Load: | 0...+30C |
| 50% Load: | 0...+40C |
| Weight: | 1100g |
| Part Nr. | UE | IE | UBA | UBL | h |
| [V] | [A] | [V] | [V] | [%] | |
| A301-300-F3 | 12 | 0...35 | 10±0,5 | 9,5±0,5 | 82 |
| A302-300-F3 | 24 | 0...15 | 20±0,8 | 19,5±0,8 | 85 |
| UE = Input Voltage Range, IE = Input Current, UBA = Battery Low Alarm, UBL = Battery Shutdown, h = Efficiency | |||||
| Note |
| Before using the DC/AC converter, please ensure that your terminal equipment has been approved by the manufacturer for operation with modified sine-wave voltage (trapezoid). |
| Labelling |
|
| Terms of Delivery |
| Minimum order quantity: 1 PKU = 1 piece |
| Manufacturer |
|
| http://www.meanwell.com |