• Open frame • Pin contact for nylon-crimp plug connector • Input voltage range: 85...264V AC • Overload protection, shutdown, reset: auto recovery • Short-circuit proof • For medical usage, EN60601-1 compliant • Low standby current consumption 0,75W
|
 |
 |
|
|
Operating Temperature:
|
-20...+60°C
|
Storage Temperature:
|
-40...+85°C
|
Overload Protection:
|
>105%
|
Overvoltage:
|
115...135%
|
Insulation Voltage
|
I/P-O/P:
|
4000V AC
|
Insulation Resistance (I/P-O/P, I/P-FG, O/P-FG: 500V DC):
|
100MW
|
Hold Up Time (230V):
|
50ms
|
Weight:
|
90g
|
I/P = Input, O/P = Output, FG = Frame Ground
|
 |
 |
|
|
Input Voltage:
|
85...264V AC (47...440Hz)
|
120...370V DC
|
AC Current (230V):
|
0,4A
|
In-Rush Current, Cold Start (230V):
|
65A
|
 |
|
|
|
|
|
|
|
|
Part Nr.
|
UA
|
DUA
|
IAN
|
IA
|
PA
|
URW
|
h
|
|
[V]
|
[%]
|
[A]
|
[A]
|
[W]
|
[mVp-p]
|
[%]
|
NFM-20-3,3 |
3,3
|
2
|
4,50
|
0...4,50
|
14,85
|
80
|
71
|
NFM-20-5 |
5
|
2
|
4,40
|
0...4,40
|
22,00
|
80
|
75
|
NFM-20-12 |
12
|
1
|
1,80
|
0...1,80
|
21,60
|
150
|
81
|
NFM-20-15 |
15
|
1
|
1,40
|
0...1,40
|
21,00
|
150
|
83
|
NFM-20-24 |
24
|
1
|
0,92
|
0...0,92
|
22,08
|
240
|
84
|
UA = Output Voltage, DUA = Output Voltage Tolerance, IAN = Output Rated Current, IA = Output Current Range, PA = DC Output Power, URW = Ripple & Noise, h = Efficiency
|
 |
|