SPS Open Frame 14,8W 3,3V/4,5A

Varenummer: 105-628
Varekode: NFM-20-3,3
Vægt: 119 g
0 stk. på lager
Vis lignende produkter i kategorien "3,3V"
Features
• Open frame
• Pin contact for nylon-crimp plug connector
• Input voltage range: 85...264V AC
• Overload protection, shutdown, reset: auto recovery
• Short-circuit proof
• For medical usage, EN60601-1 compliant
• Low standby current consumption 0,75W
Technical Specifications
Operating Temperature:
-20...+60°C
Storage Temperature:
-40...+85°C
Overload Protection:
>105%
Overvoltage:
115...135%
Insulation Voltage
I/P-O/P:
4000V AC
Insulation Resistance (I/P-O/P, I/P-FG, O/P-FG: 500V DC):
100MW
Hold Up Time (230V):
50ms
Weight:
90g
I/P = Input, O/P = Output, FG = Frame Ground
Input
Input Voltage:
85...264V AC (47...440Hz)
120...370V DC
AC Current (230V):
0,4A
In-Rush Current, Cold Start (230V):
65A
Output
Part Nr.
UA
DUA
IAN
IA
PA
URW
h
  [V]
[%]
[A]
[A]
[W]
[mVp-p]
[%]
NFM-20-3,3 3,3
2
4,50
0...4,50
14,85
80
71
NFM-20-5 5
2
4,40
0...4,40
22,00
80
75
NFM-20-12 12
1
1,80
0...1,80
21,60
150
81
NFM-20-15 15
1
1,40
0...1,40
21,00
150
83
NFM-20-24 24
1
0,92
0...0,92
22,08
240
84
UA = Output Voltage, DUA = Output Voltage Tolerance, IAN = Output Rated Current, IA = Output Current Range, PA = DC Output Power, URW = Ripple & Noise, h = Efficiency
Labelling

Manufacturer

http://www.meanwell.com
Inkl. moms
Kr. 233,20
  • v/5 – Kr. 186,56
  • v/10 – Kr. 162,50

SPS Open Frame 14,8W 3,3V/4,5A

105-628
/ NFM-20-3,3
0 stk. på lager
Features
• Open frame
• Pin contact for nylon-crimp plug connector
• Input voltage range: 85...264V AC
• Overload protection, shutdown, reset: auto recovery
• Short-circuit proof
• For medical usage, EN60601-1 compliant
• Low standby current consumption 0,75W
Technical Specifications
Operating Temperature:
-20...+60°C
Storage Temperature:
-40...+85°C
Overload Protection:
>105%
Overvoltage:
115...135%
Insulation Voltage
I/P-O/P:
4000V AC
Insulation Resistance (I/P-O/P, I/P-FG, O/P-FG: 500V DC):
100MW
Hold Up Time (230V):
50ms
Weight:
90g
I/P = Input, O/P = Output, FG = Frame Ground
Input
Input Voltage:
85...264V AC (47...440Hz)
120...370V DC
AC Current (230V):
0,4A
In-Rush Current, Cold Start (230V):
65A
Output
Part Nr.
UA
DUA
IAN
IA
PA
URW
h
  [V]
[%]
[A]
[A]
[W]
[mVp-p]
[%]
NFM-20-3,3 3,3
2
4,50
0...4,50
14,85
80
71
NFM-20-5 5
2
4,40
0...4,40
22,00
80
75
NFM-20-12 12
1
1,80
0...1,80
21,60
150
81
NFM-20-15 15
1
1,40
0...1,40
21,00
150
83
NFM-20-24 24
1
0,92
0...0,92
22,08
240
84
UA = Output Voltage, DUA = Output Voltage Tolerance, IAN = Output Rated Current, IA = Output Current Range, PA = DC Output Power, URW = Ripple & Noise, h = Efficiency
Labelling

Manufacturer

http://www.meanwell.com