SPS Case 58W 5V/24V

Varenummer: 105-430
Varekode: D-60B
Vægt: 583 g
0 stk. på lager
Vis lignende produkter i kategorien "+5V/+24V"
Gruppe: L6233
MEANWELL Switching Power Supplies
Series: D-60, ID-60
Case, Dual Output
Output: 56 to 58W

Features
Enclosed case, screw terminals
Universal input
Overload protection, pulsing hiccup shutdown, auto recovery
Protections: short circuit/over load/over voltage
ID-60: isolated outputs
Technical Specifications
Input Voltage:
85...264V AC (47...63Hz)
120...370V DC
Input Inrush Current, Max.:
45A
Leakage Current, Max.:
3,5mA
Output Voltage Adjustment:
+10/-5
Over Load Protection:
105...150%
Withstand Voltage
I/P-O/P:
3000V AC
I/P-FG:
1500V AC
O/P-FG:
500V AC
Operating Temperature:
-10...+60C
Weight:
550g
I/P = Input, O/P = Output, FG = Frame Ground

Part Nr.
UA
IA
PA1)
DUA
URN
h
 [V]
[A]
[W]
[%]
[mVp-p]
[%]
D-60A5
0,3...6
56
2
75
73
 12
0,2...4
 6
150
 
D-60B5
0,3...6
58
2
75
76
 24
0,2...2,2
 5
150
 
ID-60B5
0,3...6
58
2
100
76
 24
0,2...2,2
 8
240
 
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency, 1) The Sum of the Power Used by the Individual Channels Must Not Exceed the Total Power Rating.
Note
You will find installation material in product group L6911.
Labelling

Terms of Delivery
Minimum order quantity: 1 PKU = 1 piece
Manufacturer

http://www.meanwell.com
Inkl. moms
Kr. 300,00
  • v/10 – Kr. 268,75
Produktfiler

SPS Case 58W 5V/24V

105-430
/ D-60B
0 stk. på lager
Gruppe: L6233
MEANWELL Switching Power Supplies
Series: D-60, ID-60
Case, Dual Output
Output: 56 to 58W

Features
Enclosed case, screw terminals
Universal input
Overload protection, pulsing hiccup shutdown, auto recovery
Protections: short circuit/over load/over voltage
ID-60: isolated outputs
Technical Specifications
Input Voltage:
85...264V AC (47...63Hz)
120...370V DC
Input Inrush Current, Max.:
45A
Leakage Current, Max.:
3,5mA
Output Voltage Adjustment:
+10/-5
Over Load Protection:
105...150%
Withstand Voltage
I/P-O/P:
3000V AC
I/P-FG:
1500V AC
O/P-FG:
500V AC
Operating Temperature:
-10...+60C
Weight:
550g
I/P = Input, O/P = Output, FG = Frame Ground

Part Nr.
UA
IA
PA1)
DUA
URN
h
 [V]
[A]
[W]
[%]
[mVp-p]
[%]
D-60A5
0,3...6
56
2
75
73
 12
0,2...4
 6
150
 
D-60B5
0,3...6
58
2
75
76
 24
0,2...2,2
 5
150
 
ID-60B5
0,3...6
58
2
100
76
 24
0,2...2,2
 8
240
 
UA = Output Voltage, IA = Output Current Range, PA = Output Power, DUA = Output Voltage Tolerance, URN = Ripple & Noise, h = Efficiency, 1) The Sum of the Power Used by the Individual Channels Must Not Exceed the Total Power Rating.
Note
You will find installation material in product group L6911.
Labelling

Terms of Delivery
Minimum order quantity: 1 PKU = 1 piece
Manufacturer

http://www.meanwell.com
Produktfiler