Thermal Fuses 142°C 10(8)A
Varenummer:
131-710
Varekode: E4A142
Vægt: 14 g
5 stk.
på lager
Specifikationer
| Temperatur | 142 °C |
|---|---|
| Strøm, max. | 10 A |
Features
| • For installation on or in the heating device of electric household appliances, transformers and all types of devices • Switches off devices if the premissible operating temperature is exceeded • After activating, the fuse must be replaced • Secured in dust and dirt proof enclosure • Reacts to surrounding temperatures and is conditionally current sensitive during rated loads |
| Technical Specifications |
| Contact: | NC |
| Rated Current | |
| VDE, CSA: | 10A |
| UL: | 8A |
| Rated Voltage: | 250V AC |
| Part Nr. | TRated | TH | TMax |
| [°C] | [°C] | [°C] | |
| E4A072 | 72 | 47 | 100 |
| E4A093 | 93 | 68 | 140 |
| E4A098 | 98 | 73 | 140 |
| E4A104 | 104 | 79 | 150 |
| E4A117 | 117 | 92 | 160 |
| E4A121 | 121 | 96 | 160 |
| E4A128 | 128 | 103 | 210 |
| E4A167 | 167 | 142 | 210 |
| E4A192 | 192 | 167 | 210 |
| E4A216 | 216 | 191 | 375 |
| E4A240 | 240 | 200 | 450 |
| TRated = Rated Temperature, TH = Continuous Operating Temperature, TMax = Max. Limiting Temperature | |||
| Note |
| • The self-heating current is to be taken into consideration when using the thermal fuse • Thermal fuses with separate ventilation can lead to higher currents |
| Approvals |
![]() |
Inkl. moms
Kr. 13,95
- v/10 – Kr. 6,88
- v/100 – Kr. 4,69
Thermal Fuses 142°C 10(8)A
131-710
/ E4A142
5 stk.
på lager
Specifikationer
- Temperatur 142 °C
- Strøm, max. 10 A
Features
| • For installation on or in the heating device of electric household appliances, transformers and all types of devices • Switches off devices if the premissible operating temperature is exceeded • After activating, the fuse must be replaced • Secured in dust and dirt proof enclosure • Reacts to surrounding temperatures and is conditionally current sensitive during rated loads |
| Technical Specifications |
| Contact: | NC |
| Rated Current | |
| VDE, CSA: | 10A |
| UL: | 8A |
| Rated Voltage: | 250V AC |
| Part Nr. | TRated | TH | TMax |
| [°C] | [°C] | [°C] | |
| E4A072 | 72 | 47 | 100 |
| E4A093 | 93 | 68 | 140 |
| E4A098 | 98 | 73 | 140 |
| E4A104 | 104 | 79 | 150 |
| E4A117 | 117 | 92 | 160 |
| E4A121 | 121 | 96 | 160 |
| E4A128 | 128 | 103 | 210 |
| E4A167 | 167 | 142 | 210 |
| E4A192 | 192 | 167 | 210 |
| E4A216 | 216 | 191 | 375 |
| E4A240 | 240 | 200 | 450 |
| TRated = Rated Temperature, TH = Continuous Operating Temperature, TMax = Max. Limiting Temperature | |||
| Note |
| • The self-heating current is to be taken into consideration when using the thermal fuse • Thermal fuses with separate ventilation can lead to higher currents |
| Approvals |
![]() |